APC  Rack Cooling

(1.5kW - 23kW)

Fan products used to minimize air mixing, distribute cool air to equipment and remove heat from the rack or room


Wiring Closet Ventilation Unit

The Wiring Closet Ventilation Unit is a rapidly deployable wall and ceiling mount heat removal system designed specifically for the wiring closet environment.  By exhausting hot air from the closet to an adjacent space it allows conditioned air (entering through the Air Intake Grill) to cool the load.  Dual fans increase availability while LED status indicators and dry contact outputs enhance the units manageability.  Selectable fan speeds allow the user to choose between maximum performance and quiet operation.

Wiring Closet Ventilation Unit 
Up to 3kW of Heat Removal
Rack Air Removal Unit SX

The Rack Air Removal Unit SX captures heat, ducting it to the return air plenum and eliminating hot spots.  Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance.  With a unit-mounted LCD display uses can view temperatures at the rack, monitor alarm conditions and adjust unit set points.  The integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX.  This space-saving product mounts to the back of either the NetShelter SX or VX enclosure - requiring zero U space.

Rack Air Removal Unit 
Up to 16.5kW of Heat
Removal Per Rack
Rack Air Distribution Unit

The Rack Air Distribution Unit is a 2U fan unit that works with an existing precision air conditioning system to deliver cool air to the equipment contained in a rack enclosure.  The Rack Air Distribution Unit connects into the raised floor and pulls supply air directly into the enclosure.  This prevents the conditioned air from mixing with warmer room air before reaching the equipment.  The Rack Air Distribution Unit minimizes temperature differences between the top and bottom of the enclosure.  It also prevents hot exhaust air from recirculating to the inlet of the enclosure.  The product is recommended for rack enclosures with loads greater than 1.5kW and can provide airflow for loads up to 3.5kW.  It is also ideal for enclosures in raised floor environments where underfloor air distribution is inadequate. 

Rack Air Distribution Unit 
Up to 3.5kW of Cooling
Rack Side Air Distribution Unit

The Rack Side Air Distribution Unit is a 2U rack mountable distribution product for networking equipment or servers with side to side airflow.  It pulls in conditioned air from the front of the rack and distributes it to the side air intake of the networking equipment.  This extends equipment life by providing proper inlet temperatures.  This product is recommended for one or more networking products that are stacked consecutively in a rack.  Rack Side Air Distribution Units may be placed above and/or below the networking equipment.  Airflow pattern is user configurable via an interchangeable air turning vane.
Rack Side Air Distribution Unit 
Up to 1.5kW of Cooling


Visit www.apcc.com for complete product information.

For sales and application support for the APC Cooling Solutions email us at
sales@anu-co.com or speak with a representative at 800-848-2090.